3.8.2. System’s Vocal Identification
When giving status reports and alarm mes-
sages, the system identifies itself with a voice
recording provided by the user. This section
shows how to record this message.
Select:1.
• Main Menu
• System Auxiliaries
• User Preferences
• Voice ID
• System Message
System Message
Record
Play
Erase
Stop
Recording a New ID Message To record
a new message, press star (*) and record
the ID message (8 seconds maximum). The
Agri-Alert then plays the new message over
the speaker.
Original ID Message — Press the pound key
#” to retrieve the original ID message.
3.8.3. High Noise Alarms
The Agri-Alert can trigger an alarm if the
level of noise around surrounding it gets too
high. High noise alarms can be used warn
you if a generators motor starts running for
instance.
In order to use high noise alarms, you must
calibrate the regular level of sound surround-
in g t he Agri - A le r t a nd th e n s pe c if y th e re c og -
nition time for this type of alarm.
Select:1.
• Main Menu
• View/Modify
• High Noise Alarm
High Noise Alarm
State Enabled
Rec.Time (h:m:s) 0:00:30
Start Calibration No
Back
Set the following parameters:2.
State Select “Enabled to use high noise
alarms or select Disabled” to disable this
function.
Recognition Time Determine during how
much time the alarm condition must be
maintained before it constitutes a valid alarm
situation.
Start Calibration — Select “Yes” for the Agri-
Alert to record a sample of the regular sound
level surrounding it (this process takes about
10 seconds). Once the calibration is over, the
Agri-Alert starts monitoring the level of sound
and triggers an alarm if it gets higher than the
sample sound for a period of time exceeding
the recognition time.
System Setup3.8.
3.8.1. Standby Mode
When it is in standby mode, the Agri-Alert
stops monitoring all alarm inputs and the
“System in Standby LED turns on the front
panel. It also removes access to most of
its menus.
Select:1.
• Main Menu
• Press the Standby key
* Accessible with the Installer or Master password
only (see section 3.2).
Press Enter to select the desired system 2.
status.
Change system operating
mode
System is normal
Back
Use the arrow keys to select the normal 3.
mode or standby mode. Press Enter again
to validate.