AA800EZe rev.04
AA800EZe
3.8.4. Relay Status
The Agri-Alert has 2 built-in relays which can
be used to control various on/off devices.
Relay can either be activated manually (i.e.,
the user activates or deactivates it manually)
or they can be activated only when an alarm
occurs in a zone. Note that it is not possible
to change the status of a relay that is associ-
ated with a zone.
Refer to section 3.7.5 to assign a relay
to a zone.
The following steps allow seeing the cur-
rent status of the relays. Their status can be
change if they are not assigned to a zone.
Select:1.
• Main Menu
• View/Modify
• Output Relays
Relays
Relay 1 Activated
Relay 2 Deactivated
Back
The status of both relays is displayed. If a re-
lay is not assigned to a zone, you can change
its status by pressing Enter and using the up
or down-arrow key.
3.8.5. System Self Test
The Agri-Alert system has the capability of
testing some of its functions. To start the
test, select the following menus:
Select:1.
• Main Menu
• System Self Test
Press 2. to launch the test.
System Self Test
No Self Test Running
Cancel
Start
Outline of the test :
1. Test LEDs The system makes each zone
LED go from red to green. It then turns on
each status pilot light in red.
2. Test LCD The system tests the LCD
display. The LCD backlight is turned off and
the display displays a rectangular pattern.
3. Test Siren — Two short beeps are sent to
the siren (if a siren is hooked up).
4. Test Relays The Agri-Alert opens and
closes relays 1 and 2.
5. Test 12 VDC Output The Agri-Alert
activates and then deactivates the 12VDC
output.
6. Audio (Record / Play) The Agri-Alert
records surrounding sounds while the mes-
sage “Record” is displayed. It then plays the
recorded sound through the speaker.
7. Dialout Sequence The system launches
the dialout sequence.
System Alarm Monitoring3.8.6.
The Agri-Alert generally launches the alarm
and the call sequence when it detects an
internal system failure. It is possible to dis-
able the alarm monitoring for some of these
failures.
Select:1.
• Main Menu
• System Auxiliaries
• Monitoring
Monitoring
Battery Yes
12Vdc Yes
16Vdc Yes
Line cut Yes
Siren Yes
Back
Set the following parameters:2.
Battery / 12Vdc Output / 16Vac Supply / Line
cut / Siren — Select No” if you do not want
the alarm to sound when one of these system
failure occurs.
3.8.7. Software Version
The following menu gives the actual version
of your Agri-Alert software.
Select:1.
• Main Menu
• System Auxiliaries
• Software Version
800 EZe VX.X.XXXX
Jan 1 20XX
Base Mx Vx