INSTALLATION1.
Precautions1.1.
Precautions, Care & Mainte-1.1.1.
nance
WARNING: Read and save
these instructions!
Safety may be jeopardized if the equipment is
used in a manner not specified by the manu-
facturer. Carefully read and keep the following
instructions for future reference.
The room temperature where the alarm sys-
tem is located must always remain between
32°F and 104°F (0°C to 40°C). For Indoor
use only !
To avoid exposing the alarm system to harm-
ful gases or excessive humidity, it is prefer-
able to install it in a corridor.
Do not spray water on the alarm system ! In
order to clean it, wipe it with a damp cloth.
The e n clo sur e s ho u ld be op e ne d a n d i nsp e ct-
ed once a year for moisture. Proper care will
extend the life of the system.
For Customer Use: Enter below the serial
number located on the side of the alarm
system and keep this information for future
reference.
Model: AA800EZe
Serial number:
Date installed:
Symbols of the Manual1.1.2.
Warning. Read the following text care-
fully; it contains important information
which, if ignored, may cause the
controller to operate improperly.
High Voltage. Hazard of electrical
shock. Read the message and follow
the instructions carefully.
Pay attention. The following text
contains very useful information.
Double insulation.
Both direct and alternating current
(AC/DC).
Direct current (DC).
Alternating current (AC).
Earth Ground Terminal
Primarily used for functional earth
terminals which are generally asso-
ciated with test and measurement
circuits. These terminals are not for
safety earthing purposes but provide
an earth reference point.
1.2. Installation Procedure
To avoid electrical shocks and equipment
damage, unplug the unit before making
connections.
Determine where you want to install the 1.
system. You need an unswitched AC power
outlet and a telephone plug nearby to oper-
ate the system.
Make a list of all the sensor inputs you will 2.
be using with the Agri-Alert system.
Mount the Agri-Alert system on the wall 3.
(see section 1.3).
Connect a ground wire to the ground ter-4.
minal of the system (see section 1.4.9).
Install and connect all zone sensors and 5.
the siren. If the alarm system uses the phone,
connect the phone line to the Phone Plug-in
Card and then insert the card in the PHONE
CARD port of the Agri-Alert. If the system
uses an outside temperature sensor, connect
the sensor to the Outdoor Plug-in Card and
then insert the card in the OUTDOOR port
of the Agri-Alert. These 2 plug-in cards are
optional (see section 1.4).
Install the battery and then power up the 6.
Agri-Alert with the 16VAC wall transformer
(note that the system will not boot when
connecting the battery).
Mounting the Equipment1.3.
The Agri-Alert system should be mounted
on a wall. Use 3/16” diameter screws to
mount the enclosure on the wall. Fasten the
black caps onto the mounting holes once the
screws are tightened. Make sure the cover
can be opened easily (to open the enclosure,
pull the latch and lift the cover).
If outdoor connections are used, mount
the enclosure as close as possible to the
entry point of the outdoor wiring.