9. TECHNICAL SPECIFICATIONS
TYPE: ................................... AA800EZe
Operating Temperature: .......... 32 to 104°F (0 to 40°C)
Indoor use only
Pollution Degree: .................. 2
Installation Category: ............ 2
Altitude: ............................... 7900 Ft. Max (2000 Meters Max)
Humidity: .............................. 95% max
Cleaning: .............................. Gentle soap and water
SUPP LY:
Transformer: ......................... 16.5 VAC, 40 VA, 50/60Hz
Battery: ................................ Rechargeable, 8.4V Ni-MH 2300 mAh
OUTPUTS:
Siren : .................................. 12VDC, 1A max
12VDC Output : .................... 500mA DC max
Relays 1-2: ............................ 24VDC or AC, 2A max
10. TROUBLESHOOTING GUIDE
System Troubles10.1.
Problem Solution
The "16V
disconnected"
or "16V
unstable" icon
is displayed
and electrical
power is OK.
Make sure the 12VDC output and siren do not
exceed the circuit capacity.
Check the wall transformer and wiring.
Use a voltmeter to check voltage at the 16VAC
input terminals (16VAC minimum).
If the problem persists, contact your dealer.
The "12V fail-
ure" or "12V
unstable" icon
is displayed.
Make sure the load connected to the 12VDC
does not exceed the circuit capacity.
Check the wiring of the 12VDC output.
If the problem persists, contact your dealer.
The "Low
battery" icon is
displayed and
electrical
power is OK.
Check the transformer and wiring.
Use a voltmeter to check voltage at the 16VAC
input
terminals (16VAC minimum).
Check the battery wiring.
Use a voltmeter to check voltage at the battery
(between 6 and 9 V).
Make sure the battery respects the electrical
specifications.
If the problem persists, contact your dealer.
The "Recharge
suspended"
icon is dis-
played.
That is not a problem. The system automatically
stops charging the battery when the battery's
temperature gets too high.
The "No bat-
tery” icon is
displayed.
Make sure a battery is connected to the control-
ler.
Problem Solution
The "Dis-
connected
line" icon is
displayed.
Make sure the entry line is plugged in the right
phone jack of the phone plug-in card.
Make sure the plug-in card is properly inserted in
the "PHONE CARD" connector.
If the problem persists, unplug the telephone
jack from the phone plug-in card and contact
you dealer.
The “Phone
Card Discon-
nected" icon is
displayed.
Make sure the plug-in card is properly inserted in
the "PHONE CARD" connector.
Check the phone line wiring.
If the problem persists, unplug the phone card
and contact your dealer.
The outside temperature
reading is replaced by
3 question marks.
Make sure the outdoor card is properly inserted
in the "OUTDOOR" connector.
Check the wiring of the outdoor probe.
If the problem persists, contact you dealer.
The SIREN does not
work.
Make sure the siren load does not exceed the
circuit capacity.
If no siren is connected to the siren terminals, a
resistor must be connected in its place (1.5kΩ,½
W) or you can disable the siren output as shown
in section 3.7.6 of this manual).
If the siren impedance is too high, add a 1,5K Ω,
½W resistor to the siren circuit, as close to the
siren as possible.
The siren wire or the siren may be defective.
If the problem persists, contact your dealer.
I plugged the battery
into the controller and it
doesn't start.
On first startup, the controller needs to be pow-
ered with the 16VAC wall transformer.
The system does not
detect
any probe.
Make sure the flat cable between the top and
the bottom board inside the enclosure is properly
connected.
Make sure the removable terminal plate is prop-
erly inserted on the bottom board.
Check the wiring of the zone inputs.
If the problem persists, contact your dealer.
The system shuts down
as soon as I unplug the
wall transformer.
Make sure the battery is correctly connected.
Let the system recharge the battery for about
3 hours and a half.
Make sure the load connected to the siren and
12VDC output do not exceed the circuit capac-
ity.
If the problem persists, contact your dealer.
The system refuses to
arm.
Make sure a burglar zone is programmed.
Make sure there is no active alarm in any burglar
zone.
Login with the installer or master password.
If the problem persists, contact your dealer.