5.5.1. Bypass / Activate
The Agri-Alert only monitors alarms in ac-
tive zones (the pilot light of an active zone
is steady green when there is no alarm or is
red if there is an alarm).
The system can also stop the alarm monitor-
ing temporarily in chosen zones. To disable
the alarm detection in a zone, set the zone
status to “bypassed” (the pilot light of a
bypassed zone is amber). Only active zones
can be bypassed.
If the pilot light of a zone is off, it either
means the zone has not been activated after
having been initialized or it has not been
initialized at all. Refer to section 3.7.8 to
activate a zone for the first time or to section
3.7 to create a new zone.
Select:1.
• Main Menu
• Activate / Bypass
• Bypass Zones
Select Zone to Bypass
1 2 3 4
Yes Yes Yes Yes
5 6 7 8
Yes Yes Yes No
Back
Modify
Press the zone number on the keypad to 2.
change its status. Select “Yes” to bypass a
zone or select “No” to reactivate it.
5.5.2. View/ Modify Zone Settings
You can display zone status information at
any time and/or modify certain zone param-
eters such as set points and recognition time
without having to reconfigure the zone.
Select:1.
• Main Menu
• View/Modify
• Zone Settings
Select Zone Number
Zone 1 Zone 2 Zone 3 Zone 4
Zone 5 Zone 6 Zone 7 Zone 8
Back
Enter
Use the numeric keypad to select the 2.
desired zone. The following parameters and
status informations are displayed:
Zone 1
Type Temp
State Activated
R e a d i n g 75.7 ° F
Low T° Set. 50.0°F
High T° Set. 90.0°F
Critical T°Set. 100.0°F
Calibration 0.0°F
Rec.Time 0:00:30(h:m:s)
Back
Zone 2
Temperature zone
Zone 2
Type Dry Contact
State By passed
Reading Open
Rec.Time 0:00:30(h:m:s)
Back
Zone 3
Dry contact zone
Type — This is the type of input used by the
zone: dry contact, temperature, instant bur-
glar or delayed burglar input. *Refer to section
3.7 to modify the type of input of a zone.
Status — This is the current status of the
selected zone. Here is a list of all possible
status:
Activated — The zone is activated and there
is no alarm. *Refer to section 5.5.1 to activate a
zone.
Alarmed — The zone is activated and there is
an alarm situation in it. *Refer to section 5.4 to
get information about the alarm situation.
Bypassed — Th e zo ne is ac ti va te d b u t te m p o -
rarily bypassed. The system does not monitor
this zone input. *Refer to section 5.5.1 to bypass
or to reactivate a zone.
Disabled — The zone has been initialized but
has never been activated. The system does
not monitor this zone input. *Refer to section
3.7.8 to activate a zone for the rst time.
Reading — This is the current reading of the
zone input. If you have selected a tempera-
ture zone, the Agri-Alert show the current
temperature reading of the sensor; if it is a
dry contact zone (burglar zone or not), the
system gives the current open/close state of
the contact.
Low / High (temperature zones only) — The
Ag ri - A ler t d is p la ys t he hi g h and low t em p e ra -
ture set points. To modify these limits, press
Enter and then use the numerical keyboard
to set them. *Refer to section 3.7.4 for further
information about temperature set points.
Critical (temperature zones only) — If an
outside temperature sensor is used, the
Agri-Alert displays the critical temperature
(absolute high temperature limit). To modify
it, press Enter and then use the numerical
keyboard to enter the desired value. *Refer
to section 3.7.4 for further information about the
critical temperature limit.
Calibration (temperature zones only) — The
calibration parameter allows adjusting the
reading of a temperature probe input: the
calibration value is added or removed from
all temperatures readings made in the se-
lected zone. If the zone’s probe needs to
be calibrated, press enter and then use the
numerical keyboard to set the calibration
value (use the +/- button once to enter a
negative value). By default, the calibration
value is set to 0.
Recognition Time — Determine during how
much time the alarm condition must be
maintained before it constitutes a valid alarm
situation.